Length & Angle Sensors
One unit measures boom length and luffing angle together — one mounting point, one cable, one CANopen node.
What is a length-angle sensor?
A draw-wire length sensor with an integrated angle measurement. The wire rope tracks boom extension; the angle unit tracks the boom’s luffing angle at the same time.
- Angle range: 0–360° (−180° to +180°), accuracy ±0.2°, resolution 0.1°.
- Output: length and angle over CANopen — length on PDO1, angle on PDO2 (LG series).
- Feeds the machine’s controller or rated capacity limiter with both values from a single sensor.
Why one unit instead of two?
- Less hardware: one mounting point, one cable run, one CANopen node address.
- Synchronized data: length and angle come from the same unit, at the same cycle.
- Faster install: fewer brackets, fewer connectors, less wiring on the boom.
The range at a glance
LGH Series — 3 to 12 m
Compact length-angle sensor for crane and AWP booms. Length-only and length+angle versions available.
LG / LGH series details
LAS Angle Versions — 15 to 35 m
Long-range length-angle measurement in a carbon steel housing, for large machines and long booms.
Compare models
| Model | Length range | Angle range | Angle accuracy | Interface | Protection | Cable life |
|---|---|---|---|---|---|---|
| LGH08M | 3 / 5 / 8 m | 0–360° / −180° to +180° | ±0.2° | CANopen | IP67 (electronics chamber) | ≥150,000 |
| LGH12M | 10 / 12 m | 0–360° / −180° to +180° | ±0.2° | CANopen | IP67 (electronics chamber) | ≥100,000 |
| LAS15M | 15 m | 0–360° / −180° to +180° | ±0.2° | CANopen / 4–20 mA / 0.5–4.5 V | IP67 (electronics chamber) | ≥100,000 |
| LAS25M | 25 m | 0–360° / −180° to +180° | ±0.2° | CANopen / 4–20 mA / 0.5–4.5 V | IP67 (electronics chamber) | ≥100,000 |
| LAS35M | 35 m | 0–360° / −180° to +180° | ±0.2° | CANopen / 4–20 mA / 0.5–4.5 V | IP67 (electronics chamber) | ≥50,000 |
Length accuracy: ±0.25% FS (ranges < 8 m), ±0.5% FS (ranges ≥ 8 m). Angle resolution 0.1°. Operating temperature −40 to +85 °C (all models).
Frequently asked questions
How accurate is the angle measurement?
±0.2° accuracy, 0.1° resolution, over a 0–360° (−180° to +180°) range — on both LGH and LAS angle versions.
How do length and angle reach the controller?
Over CANopen. On the LG series, length is PDO1 and angle is PDO2; node ID, bit rate and cycle time are configurable via SDO.
Do I still need a separate tilt sensor?
For boom luffing angle, no — the length-angle unit covers it. For chassis or platform leveling you still want a dedicated tilt sensor.
Is a redundant version available?
Yes. The LG series offers a redundant dual-channel version (M12 8-pin) for safety-related applications.
Length-only or length+angle — how do I order?
Both versions share the same housing and interface. Tell us the range and whether you need the angle output, and we will confirm the exact model code.