LG / LGH Series Draw-Wire Length & Length-Angle Sensors

The standard draw-wire sensor for telescopic crane and aerial work platform booms — 3 to 12 m, CANopen, with optional integrated angle measurement.

LG08M draw-wire length sensor

LG08M (8 m class). Also available as LG12M (12 m class).

LG12M draw-wire length sensor

LG12M (12 m class).

3–12 m
Measuring length
±0.2°
Angle accuracy (angle versions)
0.1 mm
Length resolution (PDO)
IP67
Electronics chamber

Also known as: draw-wire encoder · cable extension transducer · cable-pull encoder · cable transducer · wire-actuated encoder · pull-wire encoder · cable position sensor · string encoder · length and angle sensor.

Key features

  • Ranges for every boom size — 3 / 5 / 8 / 10 / 12 m on two frame sizes (8M and 12M).
  • Optional integrated angle measurement — length + angle in one unit: 0–360° (−180° to +180°), ±0.2°.
  • CANopen, fully configurable — node ID, bit rate and cycle set over SDO; defaults (node 1, 250 kbit/s, 100 ms) match typical crane networks out of the box.
  • Redundant versions available — single or dual-channel 8-pin architecture for safety-related applications.
  • Built for outdoor mobile machinery — −40 to +85 °C, IP67 electronics chamber, AISI 316 stainless wire rope, tested to automotive-grade environmental standards.
  • Long service life — ≥150,000 cycles (8M), ≥100,000 cycles (12M). 9–36 V DC supply covers 12 V and 24 V machine systems.

How it works

The spring-loaded wire rope extends and retracts with the boom. The sensor outputs length — and angle, where fitted — over CANopen, ready to feed a rated capacity limiter, a safety controller or the machine’s own control system.

Length-only and combined length + angle versions share the same housing, interface and protocol.

Technical data

ItemLG(H)08M seriesLG(H)12M series
Measuring length0–8 m (also 3 m / 5 m versions)0–12 m (also 10 m version)
Length accuracy±0.25% FS (ranges < 8 m); ±0.5% FS (ranges ≥ 8 m)same
Length linearity±0.25% FS (ranges < 8 m); ±0.5% FS (ranges ≥ 8 m)same
Length repeatability≤ 0.3% FS≤ 0.3% FS
Length resolution (PDO)0.1 mm0.1 mm
Angle range (angle versions)0–360° / −180° to +180°0–360° / −180° to +180°
Angle accuracy / resolution±0.2° / 0.1°±0.2° / 0.1°
Output / protocolCANopenCANopen
Supply voltage9–36 V DC9–36 V DC
Current consumption18 mA @ 24 V DC (non-redundant); 36 mA (redundant)same
Max. extension speed1 m/s1 m/s
Operating / storage temperature−40 °C to +85 °C−40 °C to +85 °C
Humidity5–95% RH, non-condensingsame
Operating altitude≤ 4,000 msame
Ingress protectionIP67 (electrical chamber); IP54 (cable outlet)same
Housing materialEngineering plastic (PC)same
Wire ropeAISI 316 stainless steel, nylon-coatedsame
Service life≥ 150,000 cycles≥ 100,000 cycles
Weightapprox. 690 gapprox. 800 g
Outline dimensionsapprox. 111 × 91 × 79.5 mmapprox. 126 × 126 × 81.5 mm
Mounting3 × Ø4.2 holes, 78 × 78 mm; M4 screws, 2.4–2.7 N·m4 holes, 92 × 92 mm; M5 screws, 4.8–5.6 N·m
MarkingCE (nameplate)CE (nameplate)

Outline dimensions are approximate values read from the manual drawings; use CAD drawings for final mounting design.

CANopen interface

ItemValue
Default node ID0x01 (channel 1); 0x02 (channel 2 on dual-channel versions)
Default bit rate250 kbit/s (configurable 10 kbit/s – 1 Mbit/s via SDO)
Default cycle time100 ms (configurable 10–3,000 ms)
PDO1 — lengthCOB-ID 0x180 + node ID; signed 32-bit, 0.1 mm resolution
PDO2 — angleCOB-ID 0x280 + node ID; signed 16-bit, 0.1° resolution
HeartbeatCOB-ID 0x700 + node ID
ConfigurationSDO object dictionary (node ID, bit rate, cycle time, resolution, angle zero)
TerminationNo built-in 120 Ω terminator — fit externally as required

Pin assignment

M12, 5-pin (A-coded) — standard version

PinSignal
1CAN_GND
2+Vs (power +)
30V (power −)
4CAN_H
5CAN_L

M12, 8-pin — redundant version: pins 1–4 = power 1 +/−, CAN1_H/L; pins 5–8 = power 2 +/−, CAN2_H/L.

Model code

LGH 08M – 08 – 1 A A N – (options)

SegmentMeaning
LGHLength / length-angle sensor
08M / 12MFrame series: 8 m class / 12 m class
03 / 05 / 08 / 10 / 12Measuring length: 3 / 5 / 8 / 10 / 12 m
1Signal type: CANopen
A / DConnector: A = M12 5-pin; D = M12 8-pin
A / BAngle output: A = with angle; B = length only
Y / NSafety architecture: Y = redundant; N = non-redundant

Examples:

ModelDecoding
LG08M-08-1AAN-LLG series, 8 m class, 8 m range, CANopen, M12 5-pin, non-redundant
LG12M-12-1ABNLG series, 12 m class, 12 m range, CANopen, M12 5-pin, non-redundant

Length-only and length+angle versions are both available. Please confirm the angle configuration of a specific unit when ordering.

Standards & environmental testing

Tested to: GB/T 28046.2 / ISO 16750-2 (electrical loads, over-voltage, reverse polarity, insulation); GB/T 17626.5 (surge); IEC 60068-2-1 / -2 (cold / dry heat, −40 °C / +85 °C full-load); IEC 60068-2-14 / -38 (temperature cycling, damp heat cyclic); IEC 60068-2-6 (sinusoidal vibration 10–500 Hz); IEC 60068-2-27 (shock 500 m/s², 11 ms); IEC 60068-2-11 (neutral salt mist, 48 h); IEC 60529 (IP rating); EMC to ISO 11452-2, ISO 13766 (BCI), ISO 7637-2 and GB 34660.

Installation notes

  • Fix with three screws on a flat mounting face; keep the wire exit straight and horizontal — exit angle must stay below 3°. Use a guide pulley where the run is not straight.
  • Anchor the ring-type cable end rigidly (Ø7 mm hole); never let the extended cable snap back freely.
  • Do not mount with the cable outlet facing up (water ingress / freezing risk); a rain cover is recommended for exposed installations.

Typical applications

  • Truck-mounted and mobile cranes — telescopic boom length for rated capacity limiters (crawler crane two-section boom length, truck crane booms)
  • Loader cranes (knuckle-boom and stiff-boom)
  • Aerial work platforms — telescopic boom length and luffing angle
  • Outrigger / stabiliser extension measurement
  • Retrofit and replacement sensor for existing CANopen length measurement

Downloads

  • ZHONGZE Product Catalog (English)PDF, 24 pages — full sensor rangeDownload PDF

Datasheets, installation manuals and CAD drawings are available on request — mention the model in your inquiry.

Send us your boom length and interface.

Tell us the measuring range, whether you need the angle output, and the machine type — we will confirm the model code and a quotation.

Send Inquiry