LG / LGH Series Draw-Wire Length & Length-Angle Sensors
The standard draw-wire sensor for telescopic crane and aerial work platform booms — 3 to 12 m, CANopen, with optional integrated angle measurement.
LG08M (8 m class). Also available as LG12M (12 m class).
LG12M (12 m class).
Also known as: draw-wire encoder · cable extension transducer · cable-pull encoder · cable transducer · wire-actuated encoder · pull-wire encoder · cable position sensor · string encoder · length and angle sensor.
Key features
- Ranges for every boom size — 3 / 5 / 8 / 10 / 12 m on two frame sizes (8M and 12M).
- Optional integrated angle measurement — length + angle in one unit: 0–360° (−180° to +180°), ±0.2°.
- CANopen, fully configurable — node ID, bit rate and cycle set over SDO; defaults (node 1, 250 kbit/s, 100 ms) match typical crane networks out of the box.
- Redundant versions available — single or dual-channel 8-pin architecture for safety-related applications.
- Built for outdoor mobile machinery — −40 to +85 °C, IP67 electronics chamber, AISI 316 stainless wire rope, tested to automotive-grade environmental standards.
- Long service life — ≥150,000 cycles (8M), ≥100,000 cycles (12M). 9–36 V DC supply covers 12 V and 24 V machine systems.
How it works
The spring-loaded wire rope extends and retracts with the boom. The sensor outputs length — and angle, where fitted — over CANopen, ready to feed a rated capacity limiter, a safety controller or the machine’s own control system.
Length-only and combined length + angle versions share the same housing, interface and protocol.
Technical data
| Item | LG(H)08M series | LG(H)12M series |
|---|---|---|
| Measuring length | 0–8 m (also 3 m / 5 m versions) | 0–12 m (also 10 m version) |
| Length accuracy | ±0.25% FS (ranges < 8 m); ±0.5% FS (ranges ≥ 8 m) | same |
| Length linearity | ±0.25% FS (ranges < 8 m); ±0.5% FS (ranges ≥ 8 m) | same |
| Length repeatability | ≤ 0.3% FS | ≤ 0.3% FS |
| Length resolution (PDO) | 0.1 mm | 0.1 mm |
| Angle range (angle versions) | 0–360° / −180° to +180° | 0–360° / −180° to +180° |
| Angle accuracy / resolution | ±0.2° / 0.1° | ±0.2° / 0.1° |
| Output / protocol | CANopen | CANopen |
| Supply voltage | 9–36 V DC | 9–36 V DC |
| Current consumption | 18 mA @ 24 V DC (non-redundant); 36 mA (redundant) | same |
| Max. extension speed | 1 m/s | 1 m/s |
| Operating / storage temperature | −40 °C to +85 °C | −40 °C to +85 °C |
| Humidity | 5–95% RH, non-condensing | same |
| Operating altitude | ≤ 4,000 m | same |
| Ingress protection | IP67 (electrical chamber); IP54 (cable outlet) | same |
| Housing material | Engineering plastic (PC) | same |
| Wire rope | AISI 316 stainless steel, nylon-coated | same |
| Service life | ≥ 150,000 cycles | ≥ 100,000 cycles |
| Weight | approx. 690 g | approx. 800 g |
| Outline dimensions | approx. 111 × 91 × 79.5 mm | approx. 126 × 126 × 81.5 mm |
| Mounting | 3 × Ø4.2 holes, 78 × 78 mm; M4 screws, 2.4–2.7 N·m | 4 holes, 92 × 92 mm; M5 screws, 4.8–5.6 N·m |
| Marking | CE (nameplate) | CE (nameplate) |
Outline dimensions are approximate values read from the manual drawings; use CAD drawings for final mounting design.
CANopen interface
| Item | Value |
|---|---|
| Default node ID | 0x01 (channel 1); 0x02 (channel 2 on dual-channel versions) |
| Default bit rate | 250 kbit/s (configurable 10 kbit/s – 1 Mbit/s via SDO) |
| Default cycle time | 100 ms (configurable 10–3,000 ms) |
| PDO1 — length | COB-ID 0x180 + node ID; signed 32-bit, 0.1 mm resolution |
| PDO2 — angle | COB-ID 0x280 + node ID; signed 16-bit, 0.1° resolution |
| Heartbeat | COB-ID 0x700 + node ID |
| Configuration | SDO object dictionary (node ID, bit rate, cycle time, resolution, angle zero) |
| Termination | No built-in 120 Ω terminator — fit externally as required |
Pin assignment
M12, 5-pin (A-coded) — standard version
| Pin | Signal |
|---|---|
| 1 | CAN_GND |
| 2 | +Vs (power +) |
| 3 | 0V (power −) |
| 4 | CAN_H |
| 5 | CAN_L |
M12, 8-pin — redundant version: pins 1–4 = power 1 +/−, CAN1_H/L; pins 5–8 = power 2 +/−, CAN2_H/L.
Model code
LGH 08M – 08 – 1 A A N – (options)
| Segment | Meaning |
|---|---|
| LGH | Length / length-angle sensor |
| 08M / 12M | Frame series: 8 m class / 12 m class |
| 03 / 05 / 08 / 10 / 12 | Measuring length: 3 / 5 / 8 / 10 / 12 m |
| 1 | Signal type: CANopen |
| A / D | Connector: A = M12 5-pin; D = M12 8-pin |
| A / B | Angle output: A = with angle; B = length only |
| Y / N | Safety architecture: Y = redundant; N = non-redundant |
Examples:
| Model | Decoding |
|---|---|
| LG08M-08-1AAN-L | LG series, 8 m class, 8 m range, CANopen, M12 5-pin, non-redundant |
| LG12M-12-1ABN | LG series, 12 m class, 12 m range, CANopen, M12 5-pin, non-redundant |
Length-only and length+angle versions are both available. Please confirm the angle configuration of a specific unit when ordering.
Standards & environmental testing
Tested to: GB/T 28046.2 / ISO 16750-2 (electrical loads, over-voltage, reverse polarity, insulation); GB/T 17626.5 (surge); IEC 60068-2-1 / -2 (cold / dry heat, −40 °C / +85 °C full-load); IEC 60068-2-14 / -38 (temperature cycling, damp heat cyclic); IEC 60068-2-6 (sinusoidal vibration 10–500 Hz); IEC 60068-2-27 (shock 500 m/s², 11 ms); IEC 60068-2-11 (neutral salt mist, 48 h); IEC 60529 (IP rating); EMC to ISO 11452-2, ISO 13766 (BCI), ISO 7637-2 and GB 34660.
Installation notes
- Fix with three screws on a flat mounting face; keep the wire exit straight and horizontal — exit angle must stay below 3°. Use a guide pulley where the run is not straight.
- Anchor the ring-type cable end rigidly (Ø7 mm hole); never let the extended cable snap back freely.
- Do not mount with the cable outlet facing up (water ingress / freezing risk); a rain cover is recommended for exposed installations.
Typical applications
- Truck-mounted and mobile cranes — telescopic boom length for rated capacity limiters (crawler crane two-section boom length, truck crane booms)
- Loader cranes (knuckle-boom and stiff-boom)
- Aerial work platforms — telescopic boom length and luffing angle
- Outrigger / stabiliser extension measurement
- Retrofit and replacement sensor for existing CANopen length measurement